130 en | Terminal Operation SCSI to SATA RAID Subsystem | Administrator’s Manual
F.01U.027.802 | V1 | 2006.11 Bosch Security Systems
You may press [ESC] and select "Read/Write Test" later and choose to "View Read/Write Test-
ing Progress." If you want to stop testing the drive, select Abort Drive Testing and press
[ENTER] to proceed.
Fig. 7.77 View Read/Write Testing Progress Screen
i
NOTICE!
The disk drive on which a read/write test will be performed cannot be a spare drive (local or
global) or a member of a logical drive. The "Read/Write Test" option will not appear if the drive
is not indicated as a "New Drive" or a "Used Drive." Also, a drive formatted with a 256MB
reserved space is also excluded from selection.