SCSI to SATA RAID Subsystem | Administrator’s Manual LCD Keypad Operation | en 53
Bosch Security Systems F.01U.027.802 | V1 | 2006.11
5.4.4 Maximum Drive Capacity
Choose “Maximum Drive Capacity,” then press ENT. The maximum drive capacity refers to the
maximum capacity that will be used in each member drive.
If necessary, use the up and down arrow keys to change the maximum size that will be used
on each drive.
5.4.5 Spare Drive Assignments
The Local (Dedicated) Spare Drive can also be assigned here. Press the up or down arrow
keys to choose “Spare Drive Assignments,” then press ENT.
Available drives will be listed. Use the up or down arrow keys to browse through the drive list,
then press ENT to select the drive you wish to use as the Local Spare Drive. Press ENT again
for two seconds.
5.4.6 Disk Reserved Space
This menu allows you to see the size of disk reserved space. Default is 256MB.
5.4.7 Write Policy
This menu allows you to set the caching mode policy for this specific logical drive. “Default” is
a neutral value that is coordinated with the subsystem’s caching mode setting. Other choices
are “Write-back” and “Write-through.”