44 en | LCD Screen Messages SCSI to SATA RAID Subsystem | Administrator’s Manual
F.01U.027.802 | V1 | 2006.11 Bosch Security Systems
4.4 Logical Volume Status
Fig. 4.4 Logical Volume Status Screen
4.5 Drive Status
Fig. 4.5 Drive Status Screen
Logical Volume: The Logical Volume number.
DRV=x: The number of logical drive(s) contained in this logical vol-
ume.
Logical Volume ID Status: The unique ID number of the logical volume (randomly gen-
erated by firmware).
Logical Volume Status:
xxxMB The capacity of this logical volume.
Drive Status:
LG=x IN Initializing
LG=x LN On-line (already a member of a logical configuration)
LG=x RB Rebuilding
LG=x SB Local Spare Drive
GlobalSB Global Spare Drive
NEW DRV New drive
BAD DRV Failed drive
ABSENT Drive does not exist; an empty drive tray
MISSING Drive missing (drive was once there)
SB-MISS Spare drive missing