Table 5. SPCN Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
1011 1513 Power supply 1
1. Power supply,
Location: V1
2. System board
Location: P1
1011 1514 Power supply 1
1. Power supply,
Location: V1
2. System board
Location: P1
1011 1516 Power supply 1 missing Power supply, Location: V1
1011 1520 Power supply 2 ac source failure 1. Check power input to power
supply.
2. Power supply, Location: V2
3. System board, Location: P1
1011 1521 Power supply 1
1. Power supply 2
Location: V2
2. If the problem is not resolved,
reinstall the original supply in
location V2. Then replace power
supply 1, location V1, with the
new supply.
3. If the problem is not resolved,
reinstall the original supply in
location V1. Then replace power
supply 3 (if present), location V3,
with the new supply.
4. Replace the system board
Location: P1
1011 1522 Power supply 2 non-power fault
1. Power supply
Location: V2
2. System board
Location: P1
1011 1523 Power supply 2 domain fault
1. Power supply
Location: V2
2. System board
Location: P1
1011 1524 Power supply 2 cooling fault
1. Power supply
Location: V2
2. System board
Location: P1
1011 1526 Power supply 2 missing Power supply, Location: V2
1011 1530 Power supply 3 ac source 1. Check power input to power
supply.
2. Power supply, Location: V3
3. System board, Location: P1
Chapter 5. Error Code to FRU Index
105