Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4506 300D Memory system and scan interface
basic assurance tests detected
512MB (stacked) DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4506 300E Memory system and scan interface
basic assurance tests detected
512MB (unstacked) DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4506 301F Memory system and scan interface
basic assurance tests detected
128MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4506 303A Memory system and scan interface
basic assurance tests detected 1GB
DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4507 244C Memory system and 6xx bus
processor runtime diagnostics
detected 1W 2M 400 MHz processor
fault
Processor card, Location: P1-C1
4507 244D Memory system and 6xx bus
processor runtime diagnostics
detected 2W 4M 500 MHz processor
fault
Processor card, Location: P1-C1
4507 244E Memory system and 6xx bus
processor runtime diagnostics
detected 4W 4M 500 MHz processor
fault
Processor card, Location: P1-C1
4507 244F Memory system and 6xx bus
processor runtime diagnostics
detected 1W 2M 500 MHz processor
fault
Processor card, Location: P1-C1
4507 248A Memory system and 6xx bus
processor runtime diagnostics
detected operator panel fault
Operator panel, Location : L1
4507 24A1 Memory system and 6xx bus
processor runtime diagnostics
detected 1W 2M 450 MHz processor
fault
Processor card, Location: P1-C1
4507 24A2 Memory system and 6xx bus
processor runtime diagnostics
detected 2W 450 MHz processor
fault
Processor card, Location: P1-C1
4507 24A3 Memory system and 6xx bus
processor runtime diagnostics
detected 4W 450 MHz processor
fault
Processor card, Location: P1-C1
4507 24A4 Memory system and 6xx bus
processor runtime diagnostics
detected 6W 500 MHz processor
fault
Processor card, Location: P1-C1