Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4607 300B I/O system and 6xx bus processor
runtime diagnostics detected 128MB
DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4607 300C I/O system and 6xx bus processor
runtime diagnostics detected 256MB
DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4607 300D I/O system and 6xx bus processor
runtime diagnostics detected 512MB
(stacked) DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4607 300E I/O system and 6xx bus processor
runtime diagnostics detected 512MB
(unstacked) DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4607 301F I/O system and 6xx bus processor
runtime diagnostics detected 128MB
DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4607 303A I/O system and 6xx bus processor
runtime diagnostics detected 1GB
DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4608 244C I/O system and other bus processor
runtime diagnostics detected 1W 2M
400 MHz processor fault
Processor card, Location: P1-C1
4608 244D I/O system and other bus processor
runtime diagnostics detected 2W 4M
500 MHz processor fault
Processor card, Location: P1-C1
4608 244E I/O system and other bus processor
runtime diagnostics detected 4W 4M
500 MHz processor fault
Processor card, Location: P1-C1
4608 244F I/O system and other bus processor
runtime diagnostics detected 1W 2M
500 MHz processor fault
Processor card, Location: P1-C1
4608 248A I/O system and other bus processor
runtime diagnostics detected operator
panel fault
Operator panel, Location : L1
4608 24A1 I/O system and other bus processor
runtime diagnostics detected 1W 2M
450 MHz processor fault
Processor card, Location: P1-C1
4608 24A2 I/O system and other bus processor
runtime diagnostics detected 2W 450
MHz processor fault
Processor card, Location: P1-C1
4608 24A3 I/O system and other bus processor
runtime diagnostics detected 4W 450
MHz processor fault
Processor card, Location: P1-C1
4608 24A4 I/O system and other bus processor
runtime diagnostics detected 6W 500
MHz processor fault
Processor card, Location: P1-C1
202 Service Guide