Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4068 0222 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.5
4068 0223 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.12
4068 0224 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.6
4068 022D Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.5 x4
4068 0231 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.9
4068 0232 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.7
4068 0233 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.10
4068 0234 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.8
4068 023D Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.7 x4
4068 02FF Other bus processor runtime
diagnostics detected memory failure
on riser card 1 that cannot be
automatically isolated.
Go to “MAP 1540: Minimum
Configuration” on page 52, and run
minimum configuration for further
isolation.
4068 0300 Other bus processor runtime
diagnostics detected processor card
fault
Processor card Location: P1-C1
4068 0301 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-C1-M8
4068 0302 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-C1-M1
4068 030D Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-C1-M1
x2
4068 0311 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-C1-M7