Enable supplemental restart policy - The default setting is No. If set to Yes, the
service processor restarts the system when the system loses control as detected
by service processor surveillance, and either:
The Use OS-Defined restart policy is set to No.
OR
The Use OS-Defined restart policy is set to Yes, and the operating system
has no automatic restart policy.
Refer to “Service Processor Reboot/Restart Recovery” on page 274.
Call-Out before restart (enabled/disabled) - If a restart is necessary due to a
system fault, you can enable the service processor to call out and report the
event. This option can be valuable if the number of these events becomes
excessive, signalling a bigger problem.
v Power-On System
Allows immediate power-on of the system. For other power-on methods, see
“Powering On the System” on page 8.
v Power-Off System
Allows the user to power-off the system.
v Enable/Disable Fast System Boot
Allows the user to select the speed of the system boot.
Attention: Selecting the fast IPL results in several diagnostic tests being skipped
and a shorter memory test being run.
256 Service Guide