Compex SCSI TO S-ATA RAID Especificaciones Pagina 146

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 258
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 145
Infortrend
9-8
Figure 6 - 10: Set SAF-TE and SES Check Time
If there are remote components in your RAID enclosure being
controlled via SAF-TE/S.E.S. devices, use this function to select how
often the controller will check the status of these devices. Choose
“Periodic SAF-TE and SES Device Check Time”; then press
[ENTER]. Move the cursor to the desired interval, then press
[ENTER]. Choose Yes in the dialog box that follows to confirm the
setting.
Unless there is an I
2
C link between enclosures, there must be a valid
check time when multiple enclosures are cascaded together; e.g., an
EonStor A16F-R RAID subsystem connected to expansion JBOD
enclosures using Fibre links. Infortrend’s Fibre-to-SATA JBODs
simulate a Fibre Channel device ID and appears as a device on the
FC links.
6.3.1 Enclosure Devices Status: View Peripheral Device
Status
Select “View and edit Peripheral Devices” on the Main Menu and
press [ENTER]. Choose “View Peripheral Device Status,” then
press [ENTER] again. The device list displays.
Below is a list of peripheral devices (enclosure modules) supported
by enclosure monitoring. Monitoring of device status depends on
enclosure implementation and is accessed through different
interfaces, e.g., SAF-TE, S.E.S., or I
2
C serial bus.