Compex SCSI TO S-ATA RAID Especificaciones Pagina 214

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 258
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 213
Infortrend
B-4
B.2.3 Upgrade the Firmware Binary Only
Figure B - 2: Upgrading Firmware Binaries Using
RAIDWatch Program
1. Connect to the RAID system locally or from a remote
computer using RAIDWatch Manager. While connected to the
RAID system, there will be icon(s) with IP address specified
on the left of the menu screen. Select by double-clicking the
icon of the RAID subsystem which firmware is to be upgraded.
Select the “Configuration Parameters” icon and then select the
“System” tab. Single-click the “Download FW” check circle.
Click the Apply button to proceed. A message prompt should
display. Click Yes and then a file location prompt will appear.
2. Provide the firmware filename to the RAIDWatch Manager. It
will start to download the firmware to RAID controller.
3. Shutdown the application server(s) or application(s) which are
accessing the RAID, then reset the controller in order to use
the new downloaded firmware.
Vista de pagina 213
1 2 ... 209 210 211 212 213 214 215 216 217 218 219 ... 257 258

Comentarios a estos manuales

Sin comentarios