Data Integrity
7-3
7.1. 2 Periodic Auto-Detect Failure Drive Swap Check Time
The “Drive-Swap Check Time” is the interval at which the
controller checks to see if a failed drive has been swapped.
When a logical drive’s member drive fails, the controller
will detect the failed drive (at the selected time interval).
Once the failed drive has been swapped with a drive that
has the adequate capacity to rebuild the logical drive, the
rebuild will begin automatically
Figure 7 - 2: Set for Auto-Detect Failure Drive Swap Check
Time
Choose “Periodic Auto-Detect Failure Drive Swap Check Time”;
then press [ENTER]. Move the cursor to the desired interval; then
press [ENTER]. Choose Yes in the dialog box that follows to
confirm the setting.