Event Messages
C-23
Message
CHL:_ Host Channel ALERT: Channel Failure
What Happens?
Host channel CHL:_ link failure or disconnection occurred.
What to Do?
Check proper cabling connection and host HBA, link connection
devices, etc. Contact your RAID system supplier.
Message
SMART-Slot:_ Predictable Failure Detected-Clone Failed
What Happens?
Hard Drive(s) report SMART-detected defects. A spare drive is
commenced to clone or replace the member drive showing
defects. The cloning operation failed. The member drive
suspected of errors might have failed, or the clone process has
been interrupted, e.g., yet another member has failed or the spare
drive used for cloning has shown immanent faults.
What to Do?
Carefully check drive status and replace the unstable/failed
drive. Contact your RAID system supplier.
Message
SMART-Slot:_ Predictable Failure Detected
What Happens?
Hard drive slot:_ reported SMART-detected errors, e.g.,
abnormal rotation speed, seek time delay, etc.
What to Do?
Carefully check drive status and replace the unstable/failed
drive. Contact your RAID system supplier.
Message
SMART-Slot:_ Predictable Failure Detected-Starting Clone
What Happens?
One or more hard Drive(s) reports SMART-detected defects. Starts
using a pre-defined spare drive to clone the member drive suspected of
inherent errors. This happens when SMART detection is enabled with
the “Copy & Replace” or “Perpetual Clone” reaction schemes.
What to Do?
Press ESC to clear the message. After the cloning process, you
may consider replacing the defective drive with a good one and
configure it as a spare drive in case drive failure might happen in
the future.
Message
SMART-Slot:_ Predictable Failure Detected (TEST)
What Happens?
This results from a manually executed test command. This ensures your
disk drive supports SMART detection and report functionality.
What to Do?
Press ESC to clear the message.
Message
CHL:_ ALERT: Fibre Channel Loop Failure Detected
What Happens?
Fibre Channel loop integrity alert. Lack of bypass or nodes on a loop
caused a Fibre loop to fail.
What to Do?
Check host- or drive-side connection. Contact your RAID system
supplier.
Message
CHL:_ ALERT: Redundant Loop for CHL:_ Failure Detected
What Happens?
One of the dual loop members may have failed or been disconnected.
Make sure all channels are properly connected and topological
configurations properly set.
What to Do?
Check cabling and system installation. Contact your supplier if
no connection errors could be found.